If it doesnt improve, inspect the contacts behind the time clock for insect infestation. I hope this helps. The screw in the center point timer occasionally comes loose due to vibrations from the pump and filter. Is power reaching the time clock? Things are working fine and all of a sudden the pool pump did not start in the morning. I have an Intermatic 277/208v T104 timer controlling two 60Hz 120v outdoor lighting circuits. You will have live wires exposed and they can kill you if you touch them. To use an analog timer, you simply need to set when you want the timer to be on and off using trippers. On mine, the gears behind the dial look metal, but the motor (behind the plate) they look plastic (maybe?) },
You should always be able to switch your pump on and off manually at the timer. "wordCount": "1259",
Sound right? Then turn the breaker, that the time clock is connected to, off and back on again. My pump has a plug. Terminals 2 and 4 are used for wires going to the load (pump). If you are not sure if your timer is working or not you will first need to know if its even operational. My timer doesnt seem to be working or my pump in either speed. Since you have another switch in between the breaker and clock, the breaker will lose power when the switch is turned off. The pointer should point straight down, and you pull out on the dial, to set the correct time, aligning the current time with the pointer. I replaced a bad timer (90% sure I put the wires in the correct/same spots but there was one time when two wires got loose, so its possible I wired it wrong) and now it turns on and works, but the on/off switch doesnt work. I have changed the dog tripper and that does not take care of - Answered by a verified Electrician . Some white lithium grease on the switch can help in some cases. White is usually neutral (for 115V power), and black/red are usually hot, but sometimes people dont always use the correct wire color. To reset the time clock to the correct time, grasp the outer edges of the large yellow dial, and pull gently outward. on two occasions the plug from the pump almost melted and the second time the pool pump plug had to be replaced and i discontinued using the timer and disposed of it. My original timer worked for 5 years then the clock stopped and I heard no sound. The mechanism for the off tripper doesn't work at all when manually depressed. Or may be bent and not come together. I have a T103 24 hour dial time switch and noticed the time was off so not reading the DO NOT UNSCREW on the pointer I unscrewed it and moved the pointer to the right time and screwed it back tight. My time clock has an ant infestation! When I turned it back on now the pool clock goes backwards. Check out our online selection of new Intermatic timer clocks at InTheSwim.com! Hello. The 120V or the T101 model has 3 brass screws (terminals) underneath the plastic insulator cover. Stupid third question, but does the ON tripper say ON? I had to order new trippers as mine have been straightened too many times. It is a mechanical issue between the trippers and the switch lever. You can replace it but its really just easier to replace the entire mechanism. Having no power to your pool timer is a common problem and will occur because of three reasons: The first and easiest thing to check is the circuit breaker. I reset the breaker and tested the GCFI and I have 240V going in and out of the timer still but my pump isnt moving. Confused. Advice? "height": "219",
Before using your timer to optimize your pump, you need to determine that your pool's pH, alkalinity, and calcium hardness are 7.4 to 7.6, 100 to 150 ppm, and 150 to 400 ppm, respectively. It was always fine before. },
Its best to just write down the spots each timer is in, but remember that its a 24 hours cycle so you will need to come back within 24 hours to see if the pins moved. I have heard that perhaps a run of mis-marked motors went out and you may have a 50 Hz actually. Clock wont move, gear dont move at all. ft. home is a 3 bed, 4.0 bath property. I found a diagram showing neutral to A, line 1 to terminal 1 and line 2 to terminal 3. Intermatic 156T1978A Timer Switch Trippers, Intermatic Timer Parts Replacement for T100 Series and Intermatic Time Clocks T101, T102, T103, T104, Pool Timer On Off Clips(4 ON / 4 Off / 8 Screws) : Amazon.com.au: Home Improvement Intermatic pool timers allow you to set specific run-times for your pool filter pump, booster pump, and waterfall pump, so they operate at the most convenient time, or during non-peak energy hours. Beverly, it could be, but the cost of running wiring to the garage may be more than replacing it every 15-20 years. Just some ideas. Hello, I notice today that my pump wasnt running so I opened the pool breaker panel where the timer is and noticed the breaker was tripped. You can have as many ON an OFF trippes as you want. If moving that is difficult, you could just avoid using the switch and turn the pump off with the timeclock instead, always keeping the switch on, and maybe taping the switch, to remind people not to use the switch. Is the timer repairable, or should I just install a new one? So just turn the adjustment hold down screw on the timer pin counter clockwise about a full turn and then you will be able to slide the on or off pin to the right time on the timer wheel. That should quiet it down. Hi Joe, could be time, for new timer.
I had a power surge last night ( funny as there was no storms here ) and now my intermatic T104M timer doesnt work anymore. If the pump comes on, you definitely have power to the timer. We like that this pool timer because it is made from heavy-duty material and two grounded outlet makes it safe and durable. Donna Simpson Eating Website But What Toilet? It should be 110V or 220V AC. Lately, the timer mechanism on my old T104R does not move. Reference Manual & Buyer's Guide Another Brick in the My intermatic timer is about two years old as well. How about the GFCI outlet TEST button, is it tripped? When you flip the switch does it separate and reconnect the tabs? I replaced the pump and still nothing is moving. Hello Davy, Terry here again. My Intermatic Pool Timer still works like normal but, when it gets to the time set to turn pump on or off it doesnt. Flip off the breaker. If you pull out on the clock dial, you can turn it to set the current time, aligning with the silver down-arrow, located at 6 oclock. "width": "611",
Look for any disconnected or damaged wires leading to the motor on the rear of the clock. I have a sweeper set on auto on the second timer and it is working correctly. It is still moving and it will trip off but not on. A 50 hz timer would run faster on 60 hz, but the housing of my replacement motor says 60 hz and it is the correct replacement model. If power is reaching the clock, but the motor gears are not turning, that usually means either something is jammed in the gears, or the timer motor has burned out. Sometimes the circuit breaker will trip again as soon as you reset it or even trip when the pump starts running. I have the PF1202T timer on my pool. . Any ideas? I noticed that they had stopped. Why do we stock so many pool parts? A switch is easier to use, so you dont have to open the clock and stick wet fingers in there, and using the breaker is also less than desirable, as they can wear out faster if used as a switch. Dead as a door nail. To inspect, shut off power at the breaker, and push on the clip at the top of the box, to allow the mechanism to fall forward, and then you can inspect the vertical copper bars, and see how they shift and come apart (or not), when the switch is turned to off. You dont have two OFF trippers, right? Metal Trippers Step 1 Look on the front of the metal trippers to find the one identified as "Off" and the one labeled "On." Step 2 Loosen the screws on the face of the metal trippers. I can turn the pool pump on via the manual power lever thats located at 5 O clock on the timer. Depends maybe on what it is getting stuck on, or what is catching the tripper, and are the motor gears still turning when it gets stuck? Is it possible to do this by loosening the timer screw a bit? So if you see the 10am behind the time marker, this means that the timer has the current time of 10am. "address": "",
Just installed a new timer. Secure wire conduit to the knock out with the proper conduit connectors, and first connect the green ground wire to the green ground screw labeled GRD. do i need to do something different? Ive seen it happen from lightning strikes, or insect infestation. Take them off and inspect them and look for twists in them. Hello have a question some what related. Turn the power off at the breaker box and carefully remove the wires to the clock. With the breakers turned off, remove the mechanism from the box. Hi Jennifer, power down (shut off the breaker) again, to see if it will switch back. Inspect the tripper portion, if it looks rounder or worn, replace them. Generally, plug-in-outlet timer has gone bad, then it cannot be fixed. You will want to make sure the manual switch under the timer wheel is pushed to the on position. Thanks for your help! Inside, the 1 gear on the right side can be removed to access a metal bar. Hello. The 240V or the T104 models have 5 brass screws (terminals) underneath the plastic insulator cover. $115 Providence distortion MIJ - $120 All working perfectly Should be clear in photos which include boxes, others will be bubble wrapped and . 20 Reasons Why Pool Pumps Lose Pressure (and what to do), 25 Ways to Keep Ducks, Geese & Birds Out of Pool. No matter what caused the issue, there is typically an easy fix! Hi Chinh, if the clock gears are not moving, check the two small white wires going to the motor, on the reverse side of the timer mechanism. Hi Jeremy, I would try to pull the unit out and clean it well with compressed air and then spray with WD-40 and see if that helps. They should be straight, if not, replace them. Replace the plastic insulator cover, turn on the power, and observe the visual motor check. It stays on until I turn off the circuit breaker. Yes, seen that before! Second thing to check is the dial bent or warped, in that area where the on tripper is? After securing the wire conduit (flexible or rigid) to the box, knock out with the proper 3/4 conduit connector. If there is still no movement, test the wires coming into the time clock to see if power is reaching the time clock. You can manually engage it by turning it and then it will run and even SHUT OFF when its supposed to. I have a 2 speed pump. If thats all ok, shut off breaker and depress tab at the top, to release the mechanism from the box, and look at the copper tabs in the back. We cover T101, T103 and T104 models of mechanical pool timers. If you run rope/twine through the Air Pillow grommets, you can tie them to each other and run the rope/string to opposite sides of the pool, tying it off, so they will stay in the middle. Could be small bugs, or dirt, or both causing the problem. If you dont have the voltage here you have an issue with either the wiring or the breaker. {
If all looks tight and no foreign objects or insects are found to be in there, and the switch mechanism does not look worn (the silver part next to the tab you manually flip to turn on/off), then its probably a failing timer motor. I had to replace my 2 year old intermatic timer motor this season as gears werent turning. A timer that switches on and off at the wrong times usually occurs after a power outage. We had a few power outages the last couple of weeks, but Ive reset the time and it continues to lose time. For extra safety, shut-off the Pool breaker on the main home panel too. So what you will want to do now is to look for the circuit breaker panel and locate the circuit breaker for your Intermatic Pool Timer and then make sure it is set to the on position. "name": "In The Swim",
The timer switch has a solid click between trying to turn it on and off but since no power is going to the timer I get no juice tot he motor. 2nd black goes to -2 The circuit is protected by two ganged breakers. It worked for a day but the day after it didnt work. Pump operates off schedule Power failure earlier Reset timer Breaker was OFF for some time Reset timer 4. Align the bar with the current time and push it back into place. I have a inground pool with T10003RT4 control panel. Inspect that the gear behind the timeclock dial, is turning (very slowly), and that nothing is caught up in the gears, like sand or a lizards tail, or bugs, etc. If any of these issues occur your timer will not work properly. Im ready to send my back for a replacement. "@type": "Person",
You can always call us at 815-675-7000 M-F 8am-4:30pm CST and speak with a live technician. The tabs on the back of the timer may have fused together, or the tabs on the stationary switch at the rear of the motor, from a power surge. Pop-in a new timer mechanism, and replace the wires to the previous configuration. when the lever is in the off position the gears stop turningis this unit wired incorrectly, Natural goes to A The time is in my workshop and i normally sit next to it all the time so i know its noisier but its still working fine. For additional tripper pairs on CLOCK-DIALorder 156T1978A. AJH Trade Group also participate in other affiliate programs. Elite Swimming Pools TV 4.08K subscribers Subscribe 1.1K Share 97K views 3 years ago MIRAMAR Pool timer. I have removed the ON TRIPPER and turn the motor on at the pump and it never trips the GFCI. Timer not tripping pump on. If I have to tell you which terminals to measure, you shouldnt be doing this! If the pump doesnt come on, follow the steps below. Can the pool timer be placed inside the garage to protect it from the harsh weather. After a power failure the timer clock can start up backwards, mine has done this several times. 240V out of the timeclock (Load/Load terminals) and nothing on the motor terminal board? Articles and resources for swimming pool owners and DIYers. Using Your Timer to Optimize Your Pool Pump Download Article 1 Check the chemical balance of your pool. You can turn that yellow dial by hand CW to see if the trippers hit the off and on switch and to set the time on it. Hi Sam, check that the dial is not warped or bent, the yellow clock dial. This will disengage the dial from the . Also be sure that the ON dog is not actually an OFF dog, and that it is tightly secured to the dial edge and pushed all the way onto the dial, and straight. That will do it. "identifier": ""
If your pool pump timer is beyond repair, call a professional to replace it. If the switch simply does not move side to side, it may be a bad clock, if you cannot see what is stopping it from moving. I see a little groove worn in the corner of the on/off switch where the off timer dog touches. MLS # 6354744 Hi Cody, if you cannot see any obstruction in the motor gears, or any such mechanical issue, then I would assume an electrical issue, perhaps the wrong voltage for the clock. Any thoughts before I run out to replace it? AJH Trade Group is a participant in the Amazon Services LLC Associates Program. I not sure if this is the best timer to use. Did the power recently go out or has the circuit breaker tripped? Does the motor gradually start running slowly? Motor runs past the on dog but doesnt flip pump on? DEWENWILS Pool Pump Timer, Digital Timer Box, 2HP 40A 120-277 VAC, 7-Day 20 ON/Off Programmable Timer Switch for Water . I have a intermatic T101 and the clock doesnt move I replaced the old one due to burned out motor . Do you have an answer to why my pump wont turn off or on? Does this give you a better idea of the problem? Posted by 4 years ago. I had a thunderstorm last night and my power went off for like 3 hours. They may be fused together, or could be a lizard stuck in there, or some other foreign object or insects. Check that the motor gears are still moving also, when it gets to the switch and the dial stops moving. Hi Andy, when a clock is running slow, we might assume power outages, but when it runs fast, we might assume either a 60 hz (US) timeclock hooked up to 50 hz power service (Europe), or vice-versa, or a manufacturing defect in the gear tolerances could cause a synchronous motor timer to run fast. "headline": "Intermatic Pool Timer Troubleshooting",
Look into the visual motor check window, near the top of the timer mechanism. Terminal A (farthest to the left side) is not connected to anything. Morgan Burley (usually not). Or there could be a bad relay in the control panel, if you have ice cube style relays. I manually turn it on timer is running, it will trip pump OFF. 1100 Juanita St , Austin, TX 78704-5351 is a single-family home listed for-sale at $2,649,000. Could I send you a picture of my setup? I bought new trippers. If unsure, the White (Neutral) wire connects to the neutral buss bar in the breaker panel, and the Black (Line) wire would connect to the circuit breaker. Just above the yellow clock youll see some holes. The timer not working is for the pump. Perhaps bad wiring or a bad breaker is to blame. This pool timer is waterproof, heavy-duty, and accurate. Use a power meter set on AC volts to verify the power is off, before handling the timer mechanism. On occasion the two points that are used for setting the ON and OFF times for the pool pump get damaged or loosen. Can I wire this timer to an outlet or should I search for another solution? When I put the new one on, the trippers do not work. the trippers are even slightly damaged the timer won't work correctly. But if your circuit breaker is in the on position and your pool timer clock is not rotating and the timer is not working then you will need to call a licensed electrician to replace the timer. HI Ben, yes just remove the OFF tripper, and the clock will always be ON. Hi Jerry, it could be that the lubricant is gone, or needs more lube on the switch. No luck. There could also be other mechanical reasons for this happening, such as a disconnect in the switch. 2,767 Sq. I replaced T104 timer it runs and shuts off with no issue but once off the timer does not move or turn back on. It is twisted clockwise or counterclockwise until the correct current time lines up with the "Time" marker, which points directly downward at all times while the clock dial constantly turns. If youre not sure which is the best timer for your pool to get, we have a full blogpost for which Intermatic timer you should get for your pool. Use Green ON tripper for T100 Series timers and the silver ON tripper is for all other models. First you want to make sure there is actually power getting from the power board to the timer itself. Put a meter on the wires or trace them back to find out their voltage and source. If your 120V wires are properly colored, the White wire connects to terminal A, and the Black wire connects to terminal 1. Does the manual lever stay in the on position always? Did somthing else maybe burnt out or what is a good troubleshooting I can do before I call an electrician. I am using the breaker to turn on and off the pool pump. If you look closely, you should be able to discern if this is the problem, which could mean a new clock. When the power goes out, the timer stops. $829,900. Thanks. Its hard to give a fixed order for the steps you should take as it depends on what you found in the previous steps. 3 Baths. It started lagging again a week or so ago. },
So I connected all leads as on the directions and the clock and on off manual switch working.Not sure if timer was never connected or someone disconnected it. I also dont see any ants or other insects. P.S. Any other thoughts? Gears are moving , clock is seated correctly and everything is wired per diagram now that pool season is here I have to manually turn my pool on and off at the timer . It should loosen up after a few goes when the grease and gunt dissolve. Keeping a pool operational is expensive enough anyway, so every saving you can make helps. Some white lithium grease on the switch can help in some cases. We have a comprehensive article that covers what to do when the pump circuit breaker continually trips. As it get cooler you can cut it down to 5 or 6 hr a day . Hello, newer pool guy here. "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
VIDEO TOUR. This is the first step to confirm if there is power or not. And when switched on, power to the load terminals? Pool and Spa Expert: Mike_G2010 With the switch up it is in Auto mode. Rich. Two days ago after my pool pump shut off automatically I decided to turn it back on because the pool was still dirty. Report B BadOleRoss 0 LifeTime Supporter Apr 30, 2011 393 Lynchburg VA Aug 21, 2012 #8 #9. everything seems to be working correctly, but i can not turn the pump on or off by tripping the mechanism. But no gears or any sound. Hotels near Time Tripper, Arcueil on Tripadvisor: Find 9,014 traveller reviews, 1,228 candid photos, and prices for 2,893 hotels near Time Tripper in Arcueil, France. It should sit down nicely. This will cause issues such as the pump not switching on or off to the pump turning on or off at incorrect times. There is a second switch between the breaker and the timer. You may notice that the time pointer is loose or is moving around too much.If you find your pointer is loose, simply tighten the screw that holds the timer in place so that it doesnt wiggle around. Hi Bev, seems legit to me! I visually checked the clock motor and it was good. "caption": "In The Swim Blog"
"logo": {
And there you have it, the quick and easy ways to troubleshoot common Intermatic pool timer problems.